I/O razširitvene enote - serija FX3

I/O razširitvene enote - serija FX3

Razširitvene enote z napajanjem

SpecificationsFX2N-32ER-ES/ULFX2N-32ET-ESS/ULFX2N-48ER-DSFX2N-48ER-ES/ULFX2N-48ET-DSSFX2N-48ET-ESS/UL
Electrical data
Integrated inputs/outputs3248
Power supplyAC range (+10 %, -15 %)100–240 V100–240 V100–240 V
Frequency at ACHz50/6050/6050/60
DC range (+20 %, -30 %)24 V24 V
Max. input apparent power35 VA30 W45 VA30 W45 VA
Inrush current at ON100 V AC40 A<5 ms40 A<5 ms
200 V AC60 A<5 ms60 A<5 ms
Allowable momentary power failure time ms10510510
External service power supply (24 V DC) mA250460460
Power supply int. bus (5 V DC) mA690
Inputs
Integrated inputs1624
Min. current for logical 1 mA3.5
Max. current for logical 0 mA1.5
Response timeFor all extension units of the MELSEC FX2N series: 10 ms (at time of shipment)
Outputs
Integrated outputs1624
Output typeRelayTransistor (source)RelayTransistor (source)
Switching voltage (max.)Generally for relay version: <264 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current- per output A20.520.5
- per group* A80.8/1.6 b80.8/1.6 b
Max. switching power- inductive load W80128012
Response time ms10<0.210<0.2
Life of contacts (switching times) aFor all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
Mechanical data
Weight kg0.650.85
Dimensions (WxHxD) mm150x90x87182x90x87
 
Order information Art. no.655686556966633655716663465572
  1. Not guaranteed by Mitsubishi Electric
  2. 0.8 for 4 per group and 1.6 for 8 per group* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

Razširitvene enote brez napajanja

SpecificationsFX2N-8ER-ES/ULFX2N-8EX-ES/ULFX2N-8EYR-ES/ULFX2N-8EYT-ESS/ULFX2N-16EX-ES/ULFX2N-16EYR-ES/ULFX2N-16EYT-ESS/UL
Electrical data
Integrated inputs/outputs816
Number of occupied I/O points in the PLC16816
Power supplyAll modular extension blocks are supplied by the base unit.
Inputs
Integrated inputs4816
Min. current for logical 1 mA3.53.5
Max. current for logical 0 mA1.51.5
Response timeFor all extension blocks of the MELSEC FX2N series: 10 ms (at time of shipment)
Outputs
Integrated outputs48 16
Output typeRelayRelayTransistorRelayTransistor (source)
Switching voltage (max.)Generally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current- per output A220.520.5
- per group A880.881.6
Max. switching power- inductive load VA8080128012
Response time ms10<0.210<0.2
Life of contacts (switching times) bFor all extension units of the MELSEC FX2N series: 3,000,000 at 20 VA; 1,000,000 at 35 VA; 200,000 at 80 VA (for relay output only)
Mechanical data
Weight kg0.20.3
Dimensions (WxHxD) mm43x90x8740x90x87
 
Order information Art. no.166285166284166286166287657766558065581
  1. This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.
  2. Not guaranteed by Mitsubishi ElectricNote: To connect these modules to a FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.

Razširitvene enote brez napajanja

SpecificationsFX2NC-16EX-T-DSFX2NC-16EYR-T-DSFX2NC-16EX-DSFX2NC-16EYT-DSSFX2NC-32EX-DSFX2NC-32EYT-DSS
Electrical data
Integrated inputs/outputs16   32 
Power supplyAll modular extension blocks are supplied by the base unit.
Inputs
Integrated inputs161632
Input current X0 → X7 / X10 →∞7/57/57/5
Min. current for logical 1 X0 → X7/X10 →∞ mA4.5/3.54.5/3.54.5/3.5
Max. current for logical 0mA1.51.51.5
IsolationPhotocoupler isolation between input terminals and PC power for all base units
Response timeFor all extension units of the MELSEC FX2NC series: 10 ms (at time of shipment), partly adjustable between 0 and 60 ms in 1 ms steps (REFF, FNC51 = 0–60 ms)
Outputs
Integrated outputs161632
Output typeRelayTransistorTransistor
Switching voltage (max.) VGenerally for relay version: <240 V AC, <30 V DC; for transistor version: 5–30 V DC
Max. output current- per output A20.1/0.3 a0.1/0.3 a
- per group* A4/80.80.8
Max. switching power- inductive load VA802.4/7.2 b2.4/7.2 b
- lamp load W1000.3/0.9 c0.3/0.9 c
Response time ms10<0.2<0.2
Life of contacts (switching times)like base unit
Mechanical data
Connection typeRemovable screw terminal blocksRibbon cable connector   
Weight kg0.20.150.2
Dimensions (WxHxD) mm20.2x90x8914.6x90x8726.2x90x87
 
Order information Art. no.128152128153104503104504104505104506

0.3 A for Y0 to Y1; 0.1 A all others 7.2 W for Y0 to Y3; 2.4 W all others 0.9 W for Y0 to Y3; 0.3 W all others

* This limitation applies only per reference terminal for each group. Please observe the terminal assignments for the group identification.

Note: These modules can be combined with PLC base units of the FX3GC or FX3UC series!