Moduli za analogni nadzor serije FX3

Moduli za analogni nadzor serije FX3

Kombinirani I/O analogni moduli

SpecificationsFX2N-5A
Analog channelsInputs4
Outputs1
Input (resolution)Voltage-10–10 V (15 bit + sign), -100–100 mV (11 bit + sign)
Current-20–20 mA (14 bit + sign), 0/4–20 mA (14 bit)
Output (resolution)Voltage-10–10 V (12 bit)
Current0/4–20 mA (10 bit)
Fullscale overall accuracy±0.3–1 %*
Power supply5 V DC70 mA (from base unit)
24 V DC90 mA
Related I/O points8
Weightkg0.3
Dimensions (WxHxD)mm55x90x87
 
Order information Art. no.153740

Note: To connect the module to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required.

Analogni input moduli

SpecificationsFX2N-2ADFX3U-4ADFX3UC-4ADFX2N-8ADFX5-4ADFX5-8AD
Applicable forBase units FX3G/FX3GC/FX3GE/FX3U/FX3UCBase units FX3G/FX3GC/FX3GE/ FX3U/FX3UC/ FX5U/FX5UCBase units FX3GC/FX3UCBase units FX3G/FX3GC/FX3GE/FX3U /FX3UCBase units FX5U/FX5UC
Analog channelsInputs24848
Outputs
Analog input range0–10 V DC/ 0–5 V DC/ 0/4–20 mA-10–10 V DC/-20–20 mA/4–20 mA-10–10 V DC/ -20–20 mA/ 4–20 mA User range setting-10–10 V DC/ -20–20 mA/ Temperature detector (K, J, T, B, R, S, Pt100, Ni100) 2
ResolutionVoltage2.5 mV, 1.25 mV/ 4 µA (12 bit)0.32 mV (16 bit + sign)0.63 mV (14 bit + sign)0.3125 mV0.3125 mV (16 bit + sign)
Current1.25 µA (15 bit + sign)2.5 µA (13 bit + sign)0.625 µA0.625 µA (16 bit + sign)
Fullscale overall accuracy±1 %±0.3–1 % 1 ±0.3–0.5 % 1±0.1–0.3 % 1±0.3–±0.5 %
Power supply5 V DC20 mA (from base unit)110 mA (from base unit)100 mA (from base unit)50 mA (from base unit)40 mA (from base unit)
24 V DC50 mA (from base unit)90 mA80 mA100 mA (from base unit)100 mA (from external)40 mA (from base unit)
Related I/O points8
Weight kg0.30.20.130.40.20.3
Dimensions (WxHxD) mm43x90x8755x90x8720.2x90x7975x105x7540x90x8350x90x83
   
Order information Art. no.102869169508210090129195334430312297

1. Dependent on the ambient temperature

2. Please refer to manuals for further details of specification of temperature detectors.Notes: The FX2N-8AD can be configured to accept standard analog inputs as well as selected temperature inputs such as K, T or J type thermocouples.To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a ­FX3U-4AD to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.

Analogni output moduli

SpecificationsFX2N-2DAFX3U-4DAFX5U-4DA
Applicable forBase units FX3G/FX3GC/FX3GE/FX3U/FX3UCBase units FX3G/FX3GC/FX3GE/FX3U/FX3UC/FX5U/FX5UCBase units FX5U/FX5UC
Analog channelsInputs
Outputs24
Analog output range0–10 V DC/0–5 V DC/4–20 mA-10–10 V DC/0–20 mA/4–20 mA-10–10 V DC/0–20 mA/4–20 mA User range setting
ResolutionVoltage2.5 mV (12 bit)0.32 mV (16 bit + sign)125 µV
Current4 µA (12 bit)0.63 µA (15 bit)500 nA
Fullscale overall accuracy±1 %±0.3–0.5 %*±0.1–0.3 %*
Power supply5 V DC30 mA (from base unit)100 mA (from base unit)
24 V DC85 mA (from base unit)160 mA150 mA
Related I/O points8
Weight kg0.30.2
Dimensions (WxHxD) mm43x90x8755x90x8740x90x83
  
Order information Art. no.102868169509325715

* Dependent on the ambient temperature

Notes : To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX3U-4DA to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.

Analogni I/O moduli

SpecificationsFX3U-4AD-ADPFX3U-4DA-ADPFX3U-3A-ADP
Analog channelsInputs42
Outputs41
Analog range0–10 V DC, 4–20 mA
Resolution2.5 mV/10 µA (12 bit/11 bit )2.5 mV/4 µA (12 bit)
Overall accuracy±0.5 % */±1 %±0.5–1 %*
Power supply5 V DC15 mA (from base unit)20 mA (from base unit)
24 V DC40 mA150 mA90 mA
Related I/O points0
Weightkg0.1
Dimensions (WxHxD)mm17.6x90(106)x89.517.6x90x89.5
 
Order informationArt. no.165241165271221549

* Dependent on the ambient temperature and signal quality

Notes : When connecting the analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.

Temperaturni kontrolni moduli

SpecificationsFX3U-4LCFX5-4LC
Applicable forBase units FX3G, FX3GC, FX3GE, FX3U, FX3UC, FX5U, FX5UCBase units FX5U, FX5UC
Analog inputs4 (Thermocouple and Pt100 sensors)4 (Thermocouple, Pt100 and Pt1000 sensors )
Compensated temperature range°C-200–2300
Digital outputs4 NPN transistor open collector output points
Resolution°C0.1 or 1
Fullscale overall accuracy±0.3–0.7 % (fullscale, dependent on the ambient temperature)
Power supply5 V DC160 mA (from base unit)140 mA (from base unit)
24 V DC50 mA25 mA
Related I/O points8
Dimensions (WxHxD)mm90x90x8660x90x83
 
Order informationArt. no.232806312298

Notes : To connect these modules to a FX3UC or FX3GC base unit, an adapter FX2N-CNV-IF or a power supply FX3UC-1PS-5V is required. For the connection of a FX5U-4LC to a FX5U/FX5UC base unit, a bus conversion module FX5-CNV-BUSC resp. FX5-CNV-BUS is required.

Analogni temperaturni input adapterji

SpecificationsFX3U-4AD-TC-ADPFX3U-4AD-PT-ADPFX3U-4AD-PTW-ADPFX3U-4AD-PNK-ADPFX5-4AD-PT-ADPFX5-4AD-TC-ADP
Applicable forBase units FX3S, FX3G, FX3GC, FX3GE, FX3U, FX3UCBase units FX5U, FX5UC
Analog inputs4 (thermocouples, J or K type)4 (Pt100)4 (Pt1000 or Ni1000)4
Compensated temperature range °C-100–600 (J)/ -100–1000 (K)-50–250-100–600-50–250 (Pt1000)/ -40–110 (Ni1000)-200–850 (Pt100)/ -60–250 (Ni100)-40–750(J)/ -200–1200 (K)/ 0–1600(R, S)
Digital outputs-1000–6000 (J)/ -1000–10000 (K)-500–2500-1000–6000-500–2500 (Pt1000)/ -400–1100 (Ni1000)-2000–8500 (Pt100)/ -600–2500 (Ni100)-400–7500 (J)/ -2000–12000 (K)/ 0–16000 (R, S)
Resolution °C0.3 (J)/0.4 (K)0.10.2–0.30.1 0.1 (K,J,T), 0.1–0.3 (B,R,S)
Fullscale overall accuracy±0.5 % (fullscale)±0.5–1.0 % (fullscale)*±0.4–2.4 °C (fullscale)*±2.8–7.2 °C (fullscale)*
Power supply5 V DC15 mA (from base unit)10 mA
24 V DC45 mA50 mA20 mA
Related I/O points0
Weight kg0.1
Dimensions (WxHxD) mm17.6x90(106)x89.517.6x90(106)x74(89.1)
 
Order information Art. no.165273165272214173214172304298304299

* Dependent on the ambient temperature

Notes : When connecting the FX3 analog adapters to a FX3G, FX3S or FX3U base unit, a communications adapter is required. A direct connection without adapter is possible if these modules are connected to a FX3GC, FX3GE or FX3UC base unit.